Technical data • Complete system
24
Automation PC 3100 user's manual V0.60
2.3.1.3 Maximum ambient temperature for typical operation
Information regarding typical conditions
•
The total power of all USB interfaces on the system unit is limited to 4 W.
•
2x Gigabit Ethernet
•
No permanent 100% processor load and graphics load
•
The power consumption of the complete system is limited to 25 W. For information about the power con-
sumption of individual components, see
All values apply to non-condensing operation.
C-3965U
2.2 GHz
i3-7100U
2.4 GHz
i5-7300U
2.6 GHz
i7-7600U
2.8 GHz
All temperature values in degrees
Celsius (°C) at 500 m above sea level, non-condensing.
The maximum ambient temperature is typically derated by
1°C per 1000 meters starting at 500 meters above sea level.
5APC3100.KBUO-000
max. 15 W without USB
5APC3100.KBU1-000
max. 15 W without USB
5APC3100.KBU2-000
max. 17 W without USB
5APC3100.KBU3-000
max. 17 W without USB
Maximum ambient temperature for typical operation
60
60
55
55
What else can also be operated at the max.
ambient temperature, or is there a limitation?
5CFAST.xxxx-00
✓
✓
✓
✓
CFast cards
5CFAST.xxxx-10
✓
✓
✓
✓
5ACCLI02.DPO0-000
✓
✓
✓
✓
5ACCLI02.SDL0-000
✓
✓
✓
✓
Graphics options
5ACCLI02.SD40-000
55
55
✓
✓
5AC901.I485-00
✓
✓
✓
✓
5AC901.ICAN-00
✓
✓
✓
✓
5AC901.ICAN-01
✓
✓
✓
✓
5AC901.IHDA-00
✓
✓
✓
✓
5AC901.IRDY-00
✓
✓
✓
✓
5AC901.IPLK-00
✓
✓
✓
✓
5AC901.ISIO-00
✓
✓
✓
✓
5AC901.ISRM-00
✓
✓
✓
✓
Interface options
5AC901.IETH-00
✓
✓
✓
✓
Table 6: Ambient temperature during operation
2.3.1.4 How to determine the maximum, minimum and typical ambient temperatures
1. Select the system unit.
2. Rows "Maximum, minimum ambient temperature for worst-case operation" and "Maximum ambient temper-
ature for typical operation" show the minimum, maximum and typical ambient temperatures for the complete
system in connection with the respective system unit.
Information:
The maximum and typical temperature values correspond to operation at 500 meters above sea
level. The maximum/typical ambient temperature is typically derated by 1°C per 1000 meters (start-
ing at 500 meters above sea level).
3. If additional DVI-D/SDL options, interface options and CFast cards are installed, these components can
change the temperature limits of the APC3100 system.
4. Limitations are possible due to the mounting orientation of the Automation PC 3100. For more information,
see section
.
5.
"Information regarding typical conditions" on page 24
must be taken into account for typical ambient tem-
peratures. Testing and evaluation in this regard must be performed on-site by the user in each individual case
(temperatures can be read in BIOS or using the B&R Control Center).
If the installed component is marked by a
"✓",
it can be operated at the minimum/maximum/typical ambient tem-
perature of the complete system without problems.
If a temperature value is specified for the installed component, for example "45", then the ambient temperature of
the complete APC3100 system is not permitted to exceed this temperature.