Technical data • Complete system
Chapter 2
Technical data
Automation PC 3100 user's manual V0.60
39
2.5.12.3 Cable lengths and resolutions for SDL transmission
The following table lists the relationship between segment lengths and maximum resolution depending on the SDL
cable being used:
Resolution
SDL cable
Segment length [m]
VGA
640 x 480
SVGA
800 x 600
XGA
1024 x 768
HD
1366 x 768
SXGA
1280 x 1024
UXGA
1600 x 1200
FHD
1920 x 1080
0.8
5CASDL.0008-00 5CASDL.0008-00 5CASDL.0008-00 5CASDL.0008-00 5CASDL.0008-00 5CASDL.0008-00 5CASDL.0008-00
1.8
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
10
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
15
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
-
-
-
-
-
5CASDL.0150-03
20
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
-
-
-
5CASDL.0200-03
25
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
-
-
-
-
-
-
30
5CASDL.0300-00
5CASDL.0300-03
5CASDL.0300-00
5CASDL.0300-03
-
5CASDL.0300-13
-
5CASDL.0300-13
-
5CASDL.0300-13
-
-
-
5CASDL.0300-13
40
5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13
-
5CASDL.0400-13
Table 31: Cable lengths and resolutions for SDL transmission
2.5.12.4 Cable lengths and resolutions for DVI transfer
The following table shows the relationship between segment length and maximum resolution depending on the
DVI cable:
Resolution
DVI cable
Segment length [m]
VGA
640 x 480
SVGA
800 x 600
XGA
1024 x 768
HD
1366 x 768
SXGA
1280 x 1024
UXGA
1600 x 1200
FHD
1920 x 1080
1.8
5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00
5
5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00
Table 32: Cable lengths and resolutions for DVI transfer
The maximum cable length for DVI transfer is limited to 5 m due to the USB specification.
2.5.13 IF option 1 slot
Automation PC 3100 system units are equipped with 3 slots for interface options.
The following table lists the interface options that can be used in the IF option 1 slot.
IF option 1 slot
Model number
Short description
Interface option
5AC901.I485-00
Interface card - 1x RS232/422/458 interface - For
APC910/PPC900/APC3100/PPC3100
5AC901.ICAN-00
1)
Interface card - 1x CAN interface - For APC910/PPC900/
APC3100/PPC3100
5AC901.ICAN-01
1)
Interface card - 1x CAN interface - For APC910/PPC900/
APC3100/PPC3100
5AC901.IHDA-00
Interface card - 1x audio interface (1x MIC / 1x Line In /
1x OUT) - For APC910/PPC900/APC3100/PPC3100
5AC901.IRDY-00
Interface card - Ready relay - For APC910/PPC900/
APC3100/PPC3100
5AC901.IUPS-00
2)
UPS - For 4.5 Ah battery
5AC901.IUPS-01
3)
UPS - For 2.2 Ah battery
5AC901.ISIO-00
Interface card - System I/O - For APC910/PPC900/
APC3100/PPC3100
Interface option 1
Table 33: IF option 1 slot
1)
It is not possible to operate 2 5AC901.ICAN interface options in the IF option 1 and IF option 2 slots at the same time.
2)
UPS IF option 5AC901.IUPS-00 is only permitted to be operated with battery unit 5AC901.BUPS-00!
3)
UPS IF option 5AC901.IUPS-01 is only permitted to be operated with battery unit 5AC901.BUPS-01!