Accessories • Cables
Chapter 6 Accessories
Automation PC 3100 user's manual V0.60
159
5.7 RS232 cables
5.7.1 9A0014.xx
5.7.1.1 General information
RS232 cables are used as extension cables between two RS232 interfaces.
5.7.1.2 Order data
Model number
Short description
Figure
RS232 cables
9A0014.02
RS232 extension cable for operation of a remote display unit
with touch screen, 1.8 m
9A0014.05
RS232 extension cable for operation of a remote display unit
with touch screen, 5 m
9A0014.10
RS232 extension cable for operation of a remote display unit
with touch screen, 10 m
Table 150: 9A0014.02, 9A0014.05, 9A0014.10 - Order data
5.7.1.3 Technical data
Information:
The following specifications, properties and limit values apply only to this accessory and may deviate
from those that apply to the complete system. For the complete system in which this accessory is
installed, for example, the data specified for that complete system applies.
Model number
9A0014.02
9A0014.05
9A0014.10
General information
Certification
CE
Yes
GOST-R
-
Yes
Cable construction
Wire cross section
26 AWG
Shield
Entire cable
Outer sheathing
Color
Beige
Connector
Type
9-pin DSUB connector, male/female
Locating screw tightening torque
Max. 0.5 Nm
Operating conditions
Degree of pollution in accordance with EN 61131
Pollution degree 2
Mechanical characteristics
Dimensions
Length
1.8 m ±50 mm
5 m ±80 mm
10 m ±100 mm
Diameter
Max. 5 mm
Bend radius
Min. 70 mm
Table 151: 9A0014.02, 9A0014.05, 9A0014.10 - Technical data