Technical data • Individual components
Chapter 2
Technical data
Automation PC 3100 user's manual V0.60
83
3.5.9.3.1 Pinout
LEDs are integrated on the interface option.
Ethernet interface (ETH
1)
)
Controller
Intel I210
Wiring
S/STP (Cat 5e)
Transfer rate
10/100/1000 Mbit/s
2)
Cable length
Max. 100 m (min. Cat 5e)
LED "Speed"
On
Off
Green
100 Mbit/s
10 Mbit/s
3)
Orange
1000 Mbit/s
-
LED "Link"
On
Off
Orange
Link (indicates connection
to an Ethernet network)
Activity (blinks to indi-
cate active data transfer)
RJ45, female
1
Table 103: 5AC901.IETH-00 - Ethernet interface
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
Switching takes place automatically.
3)
The 10 Mbit/s transfer rate / connection only exists if LED "Link" is also lit at the same time.
3.5.9.3.2 Driver support
A special driver is required to operate Intel Ethernet controller I210. Drivers for approved operating systems are
available for download in the Downloads section of the B&R website (
). Windows 7, Win-
dows 10 and B&R Debian 8 are approved operating systems.
Wake-on-LAN (WoL) and PXE booting are not supported.
Information:
Only download necessary drivers from the B&R website, not from vendor websites.
3.6 Uninterruptible power supply (UPS)
With the optionally integrated UPS, the B&R industrial PC ensures that the PC system can complete write oper-
ations even after a power failure occurs. If the UPS detects a power failure, it switches to battery operation im-
mediately without interruption. All running programs are properly exited by the UPS software. The possibility of
inconsistent data is eliminated (only works if the UPS has already been configured and the driver is enabled).
Information:
•
An external panel or monitor is not buffered by the UPS and will fail if a power failure occurs.
•
For detailed information about uninterruptible power supplies, see the user's manual for the
external UPS. This can be downloaded from the B&R website.
Because the charging circuit is integrated in the housing of the B&R industrial PC, installation has been reduced
to simply attaching the connection cable to the battery unit installed next to the PC.
Special emphasis was placed on simplified maintenance when designing the battery unit. Batteries are easily
accessible from the front and can be replaced in just a few moments when servicing.
3.6.1 Requirements
•
A suitable system unit
•
UPS IF option 5AC901.IUPS-00 or 5AC901.IUPS-01
•
Battery unit 5AC901.BUPS-00 or 5AC901.BUPS-01
•
UPS connection cable: 0.5 meters (5CAUPS.0005-01), 1 meter (5CAUPS.0010-01) or 3 meters
(5CAUPS.0030-01)
•
B&R UPS configured in the ADI Control Center