![B&R Industrial Automation GmbH MAAPC3100-ENG User Manual Download Page 59](http://html1.mh-extra.com/html/bandr-industrial-automation-gmbh/maapc3100-eng/maapc3100-eng_user-manual_3089052059.webp)
Technical data • Individual components
Chapter 2
Technical data
Automation PC 3100 user's manual V0.60
59
SDL4 interface
The following overview shows the possible video signals available on the SDL4 output.
Graphics option
Video signals
5ACCLI02.SD40-000
SDL4
RJ45 connector, female
Table 56: SDL4 interface
Information:
Hot plugging display devices on the SDL4 interface for service purposes is supported by the hardware
and graphics drivers of approved operating systems. The female RJ45 connector is specified for 500
connection cycles.
Information:
If a display device with touch screen is connected to the SDL4 interface and then disconnected again
during operation (hot plugging), it may be necessary to recalibrate the touch screen.
3.4.3.3.2 Cable lengths and resolutions for SDL4 transfer
The maximum cable length for SDL4 is 100 m with a B&R
(regardless of the panel resolution).
3.4.3.3.3 SDL4 LEDs
The LEDs are located under the SDL4 interface.
SDL4 LEDs
LED
Color
Status
Explanation
On
Indicates an active SDL4 connection.
Link
Yellow
Off
No active SDL4 connection.
On
The SDL4 connection is established and OK.
Status
Yellow
Blinking
No active SDL4 connection.
LED "Status"
LED "Link"
Table 57: SDL4 LEDs