Servicing and maintenance • Repairs, complaints and replacement parts
Chapter 7
Servicing and maintenance
Automation PC 3100 user's manual V0.60
163
Chapter 7 • Servicing and maintenance
This chapter describes the servicing/maintenance work that is possible to be carried out by a trained and qualified
end user.
1 Installing and connecting the UPS battery unit
Information:
For information about installing the UPS IF option, see section "Installing interface options" on page .
Warning!
Opening the UPS battery unit is not permitted!
1. Disconnect the power supply cable to the B&R industrial PC.
2. Install the battery unit. For the drilling template, see the technical data for the respective UPS battery unit.
Ensure that the distance between the battery unit and the B&R industrial PC allows them to be connected
with the UPS cable (0.5 m, 1 m or 3 m).
4 M5 screws, 4 flat washers and 1 screw locking washer are needed for installation (min. tightening torque 1.3
Nm, screw-in depth per applicable DIN regulations and the application). These are not included in delivery.
3. Connect the UPS cable to the battery. To do so, connect the red and black wires to the power supply (orange
screw clamp terminal). Be sure to use the correct terminals (red wire to +, black wire to -)!
Connect the white and brown wires to the temperature sensor (green screw clamp terminal) (brown wire to
1, white wire to 2).
Battery connection
Temperature sensor connection
Cable clamp
Heat shrink tubing
UPS cable outer jacket
Figure 57: Connecting the UPS cable to the battery
4. Tighten the connected wires to the screw clamp terminals with a screwdriver (max. tightening torque 0.4 Nm).
5. Remove both nuts (M3) on the cable clamp and feed the UPS cable through.
6. Fasten the UPS cable using the cable clamp. Alternately tighten the previously removed nuts onto the cable
clamp (max. tightening torque 0.35 Nm).
7. Connect the 4-pin screw clamp terminal block to the UPS IF option and tighten the two screws with a screw-
driver (max. tightening torque 0.4 Nm).
2 Repairs, complaints and replacement parts
Danger!
The unauthorized opening or repair of the device can result in injury and/or extensive damage to prop-
erty. Therefore, do not attempt to perform repairs yourself. Repairs are only permitted to be performed
by authorized qualified personnel at the place of manufacture.