Technical data • Individual components
46
Automation PC 3100 user's manual V0.60
3.3.2.5 Calculating the expected service life for an existing application
The following procedure can be used to better verify whether a CFast card with SLC or MLC technology should
be used in a particular application.
•
Read the "Average erase count" of the data storage device via S.M.A.R.T.
•
Fully operate the system with the respective data storage device over a defined period of time (e.g. 1 week).
•
Determine the number of completed erase cycles with "Average erase count".
•
Calculate the expected service life using the maximum guaranteed write/erase cycles (MLC: 3000, SLC:
100,000).
Example for an MLC CFast card over the period of a week:
3.3.2.6 Dimensions
1
+0.2
-0.1
12
±
0.
1
36
.4
±
0.
15
42.8 ±0.1
41.6 ±0.13
1 ±0.1
13
.8
±
0.
1
3
±0
.0
7
2.3 ±0.1
1.15 ±0.1
0.6 ±0.07
0.
7
±0
.0
7
4.
5
±0
.1
25
.6
3
±0
.1
1 ±0.07
1
±0
.0
5
33.96 ±0.15
6.35
1 ±0.1
Top
Bottom
1 ±0.07
Figure 7: CFast card - Dimensions