Technical data • Complete system
Chapter 2
Technical data
Automation PC 3100 user's manual V0.60
17
2.1.1.2 SDL operation - Mode 2
In SDL operating mode 2, communication between the Automation Panel and B&R industrial PC is handled using
an SDL cable connected to interface "Panel In" and a USB type A/B cable connected to interface "USB In".
In addition to display data, information from the resistive touch screen and matrix keys as well as LED, service and
diagnostic data is transferred over the SDL cable. Data from the multi-touch touch screen is transferred over the
USB type A/B cable. The Automation Panel can be installed up to 5 m (USB specification) from the B&R industrial
PC. USB 2.0 data can be transferred over this distance via the USB type A/B cable. External modules are not
necessary for this.
The brightness of the display can be set using the ADI Control Center, for example.
SDL cable
USB type A/B cable
Automation Panel
with SDL/DVI Receiver
SDL mode 2
B&R industrial PC
Power supply
Grounding
Power supply
Grounding
Availability of interfaces on the Automation Panel with SDL/DVI receiver:
Panel In
✓
USB In
✓
USB 2.0
Power supply
✓
Brightness controls
x
USB1, USB2
✓
USB 2.0
COM touch screen inter-
face
x
Grounding
✓
Maximum cable length: 5 m
Requirements
•
Automation Panel with SDL/DVI receiver
•
B&R industrial PC with SDL interface
•
SDL cable, USB type A/B cable