
Accessories • Cables
Chapter 6 Accessories
Automation PC 3100 user's manual V0.60
153
5.5 SDL flex cables with extender
5.5.1 5CASDL.0xx0-13
5.5.1.1 General information
5CASDL.0xx0-13 SDL flex cables with extender are designed for use in both fixed and flexible installations (e.g.
swing arm systems).
Caution!
The cable is only permitted to be connected or disconnected when the power is switched off.
5.5.1.2 Order data
Model number
Short description
Figure
SDL cables flex
5CASDL.0300-13
SDL flex cable with extender - 30 m
5CASDL.0400-13
SDL flex cable with extender - 40 m
5CASDL.0430-13
SDL flex cable with extender - 43 m
Table 146: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Order data
5.5.1.3 Technical data
Information:
The following specifications, properties and limit values apply only to this accessory and may deviate
from those that apply to the complete system. For the complete system in which this accessory is
installed, for example, the data specified for that complete system applies.
Model number
5CASDL.0300-13
5CASDL.0400-13
5CASDL.0430-13
General information
Certification
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
DNV GL
Temperature:
B
(0 - 55°C)
Humidity:
B
(up to 100%)
Vibration:
A
(0.7 g)
EMC:
B
(Bridge and open deck)
1)
GOST-R
Yes
Cable construction
Wire cross section
24 AWG (control wires)
26 AWG (DVI, USB, data)
Features
Silicone- and halogen-free
Shield
Individual cable pairs, entire cable
Complete shielding
Aluminum-clad foil and tinned copper braiding
Outer sheathing
Material
Special semi-matte TMPU
Color
Black
Labeling
(B&R) SDL cable (UL) AWM 20236 80°C 30 V E63216
Connector
Type
2x DVI-D (24+1), male
Connection cycles
Min. 200
Contacts
Gold-plated
Mechanical protection
Metal cover with crimped strain relief
Locating screw tightening torque
Max. 0.5 Nm
Electrical characteristics
Operating voltage
≤30 V
Test voltage
Wire/Wire
1 kV
Wire/Shield
0.5 kV
Wave impedance
100 ±10 Ω
Conductor resistance
24 AWG
≤95 Ω/km
26 AWG
≤145 Ω/km
Insulation resistance
>200 MΩ/km
Table 147: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data