Technical data • Individual components
48
Automation PC 3100 user's manual V0.60
Model number
5CFAST.2048-00
5CFAST.4096-00
5CFAST.8192-00
5CFAST.016G-00
5CFAST.032G-00
Certification
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
2)
DNV GL
Temperature:
B
(0 - 55°C)
Humidity:
B
(up to 100%)
Vibration:
A
(0.7 g)
EMC:
B
(Bridge and open deck)
3)
GOST-R
Yes
Endurance
1)
SLC flash
Yes
Guaranteed data volume
Guaranteed
4)
185 TBW
371 TBW
745 TBW
1468 TBW
2937 TBW
Clear/Write cycles
Guaranteed
100,000
Wear leveling
Static
S.M.A.R.T. support
Yes
Support
Hardware
APC3100, APC2100, APC910, PPC3100, PPC2100, PPC900
Operating systems
Windows 10 IoT Enterprise LTSB
64-bit
No
No
No
No
Yes
Windows Embedded 8.1 Industry
Pro 32-bit
No
No
No
Yes
Yes
Windows Embedded 8.1 Industry
Pro 64-bit
No
No
No
No
Yes
Windows 7 32-bit
No
No
No
Yes
Yes
Windows 7 64-bit
No
No
No
No
Yes
Windows Embedded Standard 7,
32-bit
No
No
No
Yes
Yes
Windows Embedded Standard 7,
64-bit
No
No
No
Yes
Yes
Windows XP Professional
No
Yes
Yes
Yes
Yes
Windows Embedded Standard 2009
Yes
Debian 8
No
Yes
Yes
Yes
Yes
Software
PVI Transfer
≥V4.0.0.8 (part of PVI Development Setup ≥V3.0.2.3014)
B&R Embedded OS Installer
≥V3.10
≥V3.10
≥V3.10
≥V3.20
≥V3.21
Environmental conditions
Temperature
Operation
-40 to 85°C
Storage
-50 to 100°C
Transport
-50 to 100°C
Relative humidity
Operation
Max. 85% at 85°C, non-condensing
Storage
Max. 85% at 85°C, non-condensing
Transport
Max. 85% at 85°C, non-condensing
Vibration
Operation
10 to 2000 Hz: 20 g peak
Storage
10 to 2000 Hz: 20 g peak
Transport
10 to 2000 Hz: 20 g peak
Shock
Operation
1500 g peak, 0.5 ms
Storage
1500 g peak, 0.5 ms
Transport
1500 g peak, 0.5 ms
Mechanical characteristics
Dimensions
Width
42.8 ±0.10 mm
Length
36.4 ±0.10 mm
Depth
3.6 ±0.10 mm
Weight
10 g
Table 41: 5CFAST.2048-00, 5CFAST.4096-00, 5CFAST.8192-00, 5CFAST.016G-00, 5CFAST.032G-00 - Technical data
1)
Per JEDEC (JESD47), EOL conditions are not permitted to be reached before 18 months. A higher average of the daily write workload reduces the expected
service life and data retention of the data storage device.
2)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
3)
Yes, although applies only if all components installed in the complete system have this certification.
4)
TBW = Terabytes written
Sequential access without a file system