www.balluff.com
31
3021
h
Parameters for application profile 0
00
h
U8
r
Highest subindex supported
08
h
01
h
- 05
h
S8
rw
Reserved
0
d
06
h
U16
rw
Output filter
100
d
7.2.7
07
h
U8
rw
Moving average filter TPDO1
10
d
7.2.8
08
h
U8
rw
Moving average filter TPDO2
0
d
3022
h
Parameters for Application Profile 1
00
h
U8
r
Highest subindex supported
08
h
01
h
- 05
h
S8
rw
Reserved
0
d
06
h
U16
rw
Output filter
0
d
7.2.7
07
h
U8
rw
Moving average filter TPDO1
0
d
7.2.8
08
h
U8
rw
Moving average filter TPDO2
0
d
3023
h
Parameters for Application Profile 2
00
h
U8
r
Highest subindex supported
08
h
01
h
- 05
h
S8
rw
Reserved
0
d
06
h
U16
rw
Output filter
50
d
7.2.7
07
h
U8
rw
Moving average filter TPDO1
10
d
7.2.8
08
h
U8
rw
Moving average filter TPDO2
0
d
3024
h
Parameters for Application Profile 3
00
h
U8
r
Highest subindex supported
08
h
01
h
- 05
h
S8
rw
Reserved
0
d
06
h
U16
rw
Output filter
100
d
7.2.7
07
h
U8
rw
Moving average filter TPDO1
10
d
7.2.8
08
h
U8
rw
Moving average filter TPDO2
0
d
3025
h
Parameters for Application Profile 4
(future use)
00
h
U8
r
Highest subindex supported
08
h
01
h
- 08
h
S8
rw
Reserved
0
d
3026
h
Parameters for Application Profile 5
(future use)
00
h
U8
r
Highest subindex supported
08
h
01
h
- 08
h
S8
rw
Reserved
0
d
3027
h
Parameters for Application Profile 6
(future use)
00
h
U8
r
Highest subindex supported
08
h
01
h
- 08
h
S8
rw
Reserved
0
d
3028
h
Parameters for Application Profile
7(future use)
00
h
U8
r
Highest subindex supported
08
h
01
h
- 08
h
S8
rw
Reserved
0
d
Tabelle 25
– Manufacturer-specific profile
Um herstellerspezifische Parameter dauerhaft im EEPROM des Geräts zu speichern, verwenden Sie nur
das CAN-Objekt 1010h, da sonst die Änderungen nach einem Power-Cycle verloren gehen. Alle nicht in der
Tabelle beschriebenen Indizes bzw. Subindizes sind ausschließlich für den werkseitigen Gebrauch reserviert..