9 Control Input/Output
58
© Copyright Reserved Autonics Co., Ltd.
9.1.2.10
Servo On/Off
It is for adjusting shaft position of motor by external force manually.
When Servo is Off in built-in brake type, brake turns into lock status. the brake status can be
changed as release status manually by using Brake ON/OFF signal. For more information,
refer to ‘9.1.2.16 Brake ON/OFF’.
Servo On/Off signal is ON over 1.5 msec or 10 msec.
: It recognizes as servo off signal and the phase current of motor is blocked and torque
is released.
Servo On indicator, In-Position Output and the indicator turn OFF.
Servo On/Off signal is Off over 1.5 msec or 10 msec.
: It recognizes as servo on signal and the phase current of motor is supplied and torque
is return.
Servo On indicator, In-Position Output and the indicator turn ON.
Only available when motor is stopped. Make sure the motor completely stop before use.