13 Protection Function
126
© Copyright Reserved Autonics Co., Ltd.
No. of
flashing
Alarm type Desctiptions
Causes
Troubleshooting
12 (
EC
) In-Position
error
When position
error (over 1) is
kept over 3 sec,
after motor
stopped.
1. Over load
2. Lack of stop torque.
1. Change operation condition or
reduce load so that sudden load
fluctuation does not occur.
2. Increase stop torque as 50% or
use the other motor with higher
torque.
13 (
ED
) Memory error
When memory
error is detected
as power supplied
1. EEPROM error
1. Replace EEPROM parts.