10 Drive
© Copyright Reserved Autonics Co., Ltd.
77
10.1.5
Home Search
According to the setting of “HOME Active Level” parameter, it operates home search drive by
[H] or [L] input.
Home search drive
1st
Drive mode
: It is available to set the home search mode combining with “HMD0”, “HMD1”.
2nd
Drive
: When “HOME” signal inputs, it operates home search according to the set mode.
3rd
Stop
: When “STOP” signal inputs or limit signal of the direction inputs, it stops.
4th
Emergency stop
: When “EMG” signal inputs, it stops emergently.
5th
Complete
: When the home is found, home search ends.
If the “Power On Home Search” parameter is enabled, the home search operates when
the power is applied. If it is set to zero point home search, Home search mode error
alarm (
EH
) occurs.