CHAPTER 5. AUXILIARY EQUIPMENT INSTALLATION
5 .
6 .
7 .
8 .
9 .
For 110-type hardware, install a yellow (auxiliary) label on the
110-type terminal block. For 66-type hardware, write the lead
designations on the 66-type connecting block with a felt-tipped pen.
Remove the cover from the 36A voice coupler, and install the voice
coupler.
At the 36A voice coupler:
Make connections to the 110-type wiring block on the
ED-1E443-10 intra-connection panel (Figure 5-14).
Connect a 2012D transformer to terminals AC and ACG.
Install the cover.
Install recorded announcement equipment per manufacturer’s
instructions.
Plug the 2012D transformer into a 117-volt ac receptacle not under
control of a wall switch.
Install patch cord/jumper wires at the cross-connect field.
Administer per AT&T System 75 and System 75 XE—Implementation
( 5 5 5 - 2 0 0 - 6 5 1 ) a n d AT&T System 75 and System 75
XE—Administration (555-200-500).
Digital Announcer
Requirements
The Cook Electric digital announcer can be mounted in the auxiliary
cabinet on a 23-inch relay rack. The relay rack includes the side bracket
kit that consists of two side brackets and four mounting screws. The
vertical height is 1.75 inches. If the digital announcer is located outside
the auxiliary cabinet, it is powered by a 117-volt ac adapter furnished by
Cook Electric. If the digital announcer is mounted inside the auxiliary
cabinet, -48V dc power is provided by a rectifier mounted at the base of
the cabinet. The alarm panel is mounted at the top of the cabinet.
5-26
●
●
●
10.
11.
Summary of Contents for System 75
Page 1: ...AT T AT T System 75 and System 75 XE Wiring...
Page 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Page 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Page 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Page 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Page 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Page 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Page 98: ...Typical System Equipment Room Floor Plans 3 15...
Page 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Page 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Page 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Page 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Page 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Page 212: ...Adjunct Powering 4 15...
Page 214: ...Adjunct Powering 4 17...
Page 216: ...Patch Cord Jumper Installation And Administration 4 19...
Page 241: ...CHAPTER 4 STATION WIRING 4 44...
Page 244: ...Miscellaneous Wiring Installation 4 47...
Page 246: ...Miscellaneous Wiring Installation 4 49...
Page 252: ...Miscellaneous Wiring Installation 4 55...
Page 254: ...Miscellaneous Wiring Installation 4 57...
Page 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Page 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...