CHAPTER 3. EQUIPMENT ROOM DESIGN
site/satellite location or adapter. Staggered-finger cables are
recommended for all multiple 25-pair station cables.
Staggered-finger cables are available in both double-ended and
single-ended types.
●
●
●
Bulk Cable—This cable is the same as the connectorized 25-pair
cable or multiple 25-pair cable; however, the bulk cable is not
equipped with connectors. Use this cable between the equipment
room and satellite closets when both are equipped with
punch-down type terminal/connecting blocks.
Nonconnectorized 4-pair station cable—Use this cable when
4-pair station cables are to be field-terminated on the 110-type
terminal blocks/66-type connecting blocks in the equipment room
or satellite closet and the information outlets require push-on
connections.
Single modular plug-ended 4-pair station cable(Figure 3-60)—Use
this cable between adapters and information outlets that require
push-on connections. It can also be used when 4-pair station
cables are field-terminated on the 110-type terminal
blocks/66-type connecting blocks in the equipment room or
satellite closet and modularly connected to information outlets.
The station cables are available in the following lengths:
●
●
●
●
●
●
●
10 feet
25 feet
50 feet
75 feet
100 feet
150 feet
200 feet.
●
Double modular plug-ended 4-pair station cable—Use this cable
to provide nonstandard length runs between adapters and
information outlets with push-on connections. It can also be used
between adapters and modularly connected information outlets. It
is available in the same lengths as the single modular plug-ended
cable (see Note).
3-92
Summary of Contents for System 75
Page 1: ...AT T AT T System 75 and System 75 XE Wiring...
Page 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Page 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Page 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Page 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Page 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Page 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Page 98: ...Typical System Equipment Room Floor Plans 3 15...
Page 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Page 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Page 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Page 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Page 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Page 212: ...Adjunct Powering 4 15...
Page 214: ...Adjunct Powering 4 17...
Page 216: ...Patch Cord Jumper Installation And Administration 4 19...
Page 241: ...CHAPTER 4 STATION WIRING 4 44...
Page 244: ...Miscellaneous Wiring Installation 4 47...
Page 246: ...Miscellaneous Wiring Installation 4 49...
Page 252: ...Miscellaneous Wiring Installation 4 55...
Page 254: ...Miscellaneous Wiring Installation 4 57...
Page 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Page 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...