110-Type Hardware Description
Test Cords
The D test cord provides test access to one pair of wires without
removing any jumpers.
D TEST CORD ORDERING INFORMATION
Length
Cord
D Test Cord 4 ft
402 023 949
D Test Cord 8 ft
402 023 956
Comcode
Jumpers
Solid wire jumpers can be used to make cross-connections instead of
the 1- and 3-pair patch cords. The jumpers are terminated on the
connecting blocks with an impact tool.
Jumper Wire
JUMPER WIRE ORDERING INFORMATION
Description
Comcode
(Order by Footage)
DT 24M-Y/BL/R/G
2-Pair
103 252 557
DT 24P-W/BRN
1-Pair
102 484 045
DT 24P-Y/BL
1-Pair
102 379 195
DT 24P-Y/G
1-Pair
103 252 565
DT 24P-Y/O
1-Pair
103 252 573
DT 24P-Y/R
1-Pair
103 252 581
Tools
The following tools are required terminate the wires/jumpers on
field-terminated wiring blocks:
●
●
●
The D impact tool (AT-8762) is a single-wire termination tool
The 788J1 impact tool will terminate five pairs of wire at a time
The 788K1 conductor retention tool is used to secure cable pairs
in the wiring blocks when connecting blocks are being removed
from the wiring blocks.
2 - 2 1
Summary of Contents for System 75
Page 1: ...AT T AT T System 75 and System 75 XE Wiring...
Page 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Page 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Page 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Page 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Page 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Page 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Page 98: ...Typical System Equipment Room Floor Plans 3 15...
Page 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Page 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Page 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Page 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Page 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Page 212: ...Adjunct Powering 4 15...
Page 214: ...Adjunct Powering 4 17...
Page 216: ...Patch Cord Jumper Installation And Administration 4 19...
Page 241: ...CHAPTER 4 STATION WIRING 4 44...
Page 244: ...Miscellaneous Wiring Installation 4 47...
Page 246: ...Miscellaneous Wiring Installation 4 49...
Page 252: ...Miscellaneous Wiring Installation 4 55...
Page 254: ...Miscellaneous Wiring Installation 4 57...
Page 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Page 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...