CHAPTER 5. AUXILIARY EQUIPMENT INSTALLATION
●
●
●
Journal Printer—R1V3 Only
Customer-provided terminals and host computers
SMDR
PDMs are connected to TN754 digital line circuit packs and are
mounted individually or in a 71A data mounting. Each 71A data
mounting can contain eight PDMs. This guide contains only the
information required to connect the PDMs to the switch. PDM installation
and testing information is contained in AT&T System 75 User’s
Guide—Processor Data Module, 999-700-028.
The data mounting is connected by an A25D/B25A cable through the
cross-connect field to a TN754 digital line circuit pack. The PDMs can
also be mounted and connected individually through the cross-connect
field.
Installation
Connection to Data Mounting (Figure 5-21)
1. From the Data Module Form, determine port assignment of PDMs:
EXAMPLE:
Carrier Slot Circuit
Port Number
B
0 2
01
2. Connect an A25D (for 110-type hardware) or B25A for 66-type
hardware) cable to the DCP-LINE connector on the rear of the data
mounting.
3. Route the cable from the data mounting to the station side of the
cross-connect field.
4. For 110-type hardware, install a yellow (auxiliary) label on the
110-type terminal block. For 66-type hardware, write the lead
designations on the 66-type connecting block with a felt-tipped pen.
5. Connect patch cords/jumper wires at cross-connect field (Figure
5-21).
6. Administer per AT&T System 75 and System 75 XE—lmplementation
(555-200-651) and AT&T System 75 and System 75 XE—Administration
(555-200-500).
5-37
Summary of Contents for System 75
Page 1: ...AT T AT T System 75 and System 75 XE Wiring...
Page 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Page 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Page 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Page 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Page 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Page 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Page 98: ...Typical System Equipment Room Floor Plans 3 15...
Page 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Page 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Page 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Page 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Page 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Page 212: ...Adjunct Powering 4 15...
Page 214: ...Adjunct Powering 4 17...
Page 216: ...Patch Cord Jumper Installation And Administration 4 19...
Page 241: ...CHAPTER 4 STATION WIRING 4 44...
Page 244: ...Miscellaneous Wiring Installation 4 47...
Page 246: ...Miscellaneous Wiring Installation 4 49...
Page 252: ...Miscellaneous Wiring Installation 4 55...
Page 254: ...Miscellaneous Wiring Installation 4 57...
Page 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Page 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...