CHAPTER 4. STATION WIRING
OPTION SWITCH
TRUNK TYPE SWITCHES
LOOP START
GROUND START
1 2
BOTH SWITCHES MUST BE THROWN
FOR TRUNK TYPE
CIRCUIT
NUMBER
1
2
3
4
5
1 AND 2
3 AND 4
5 AND 6
7 AND 8
9 AND 10
SWITCHES
USE SMALL SCREWDRIVER TO MOVE SWITCH
Figure 4-25. 574-5 Power Transfer Unit Option Switches
When ground start trunks are used, the transfer unit automatically
provides ground start for each trunk without requiring any special wiring
at the telephone used for emergency transfer service.
Figures 4-26 and 4-27 shows the connections on 110-type terminal
blocks and 66-type connecting blocks, respectively, at the trunk/auxiliary
cross-connect field for a telephone used only for emergency transfer.
Figures 4-28 and 4-29 show the connections on 110-type terminal
blocks and 66-type connecting blocks, respectively, at the trunk/auxiliary
cross-connect field for a telephone used for emergency transfer as well
as a normal extension.
4-46
Summary of Contents for System 75
Page 1: ...AT T AT T System 75 and System 75 XE Wiring...
Page 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Page 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Page 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Page 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Page 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Page 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Page 98: ...Typical System Equipment Room Floor Plans 3 15...
Page 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Page 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Page 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Page 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Page 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Page 212: ...Adjunct Powering 4 15...
Page 214: ...Adjunct Powering 4 17...
Page 216: ...Patch Cord Jumper Installation And Administration 4 19...
Page 241: ...CHAPTER 4 STATION WIRING 4 44...
Page 244: ...Miscellaneous Wiring Installation 4 47...
Page 246: ...Miscellaneous Wiring Installation 4 49...
Page 252: ...Miscellaneous Wiring Installation 4 55...
Page 254: ...Miscellaneous Wiring Installation 4 57...
Page 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Page 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...