short circuit to positive / short circuit to negative / open circuit, overcurrent, excessive internal
temperature
Error cause
•
Short-circuit to positive: excessive voltage detected on PIN 29 or 41 of the 7SM control unit.
If short circuit to negative: no voltage has been detected. If open circuit: an interruption or
excessive absorption of amperes or overheating of the control unit was detected
Troubleshooting
•
Short-circuit to positive: disconnect the throttle body connector, turn the key OK and check
the voltage at PIN 3: if a voltage greater than or equal to 5 V is read, there is a short circuit
of the relative cable, if the voltage is zero, replace the throttle body
•
If short circuit to negative: disconnect the throttle body connector, turn the key ON and check
if PIN 3 has continuity with the vehicle ground: if there is continuity restore the wiring harness,
if there is no continuity replace the throttle body
•
If there is open circuit, overcurrent, excessive internal temperature: check the throttle body
connector and the control unit connector: if not ok restore, if everything is ok disconnect the
connector of the throttle body and the control unit connector and check cable continuity; if
there is no continuity, restore the cable harness. If there is continuity, with the throttle body
connector connected, check that the resistance, from the throttle control unit connector,
between PIN 29 and 41 is within 1 and 2.5 Ohm; if not ok replace the throttle body, if ok
check that the throttle body is not mechanically blocked: if blocked, remove the cause or
replace the body, if not blocked replace the control unit
Front throttle valve control circuit P1119
•
short circuit to positive / short circuit to negative / open circuit, overvoltage, excessive internal
temperature circuit open
Error cause
•
Short-circuit to positive: excessive voltage detected on PIN 3 or 15 of the 7SM control unit.
If short circuit to negative: no voltage has been detected. If open circuit: an interruption or
excessive absorption of amperes or overheating of the control unit was detected
Troubleshooting
•
Short-circuit to positive: disconnect the throttle body connector, turn the key OK and check
the voltage at PIN 3: if a voltage greater than or equal to 5 V is read, there is a short circuit
of the relative cable, if the voltage is zero, replace the throttle body
•
If short circuit to negative: disconnect the throttle body connector, turn the key ON and check
if PIN 3 has continuity with the vehicle ground: if there is continuity restore the wiring harness,
if there is no continuity replace the throttle body
•
If there is open circuit, overcurrent, excessive internal temperature: check the throttle body
connector and the control unit connector: if not ok restore, if everything is ok disconnect the
RSV4 1100 Factory
Electrical system
ELE SYS - 191
Summary of Contents for RSV4 1100 Factory
Page 1: ...SERVICE STATION MANUAL 2Q000401 RSV4 1100 Factory ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 63: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 89: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 245: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 270: ...INDEX OF TOPICS ENGINE ENG ...
Page 384: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 387: ... Remove the fuel pump Injection RSV4 1100 Factory Power supply P SUPP 387 ...
Page 393: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 417: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 455: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 457: ...Operating diagram ABS functional diagram key RSV4 1100 Factory Braking system BRAK SYS 457 ...
Page 488: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 499: ...INDEX OF TOPICS BODYWORK BODYW ...
Page 540: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 546: ... Fit the two seater saddle Pre delivery RSV4 1100 Factory PRE DE 546 ...