5.5.6.2 Ilimit
This menu allows the user to set the upper and or lower parameter value limits for current.
5.5.6.3 Plimit
This menu allows the user to set the upper and or lower parameter value limits for power.
5.5.6.4 Rlimit
This menu allows the user to set the upper and or lower parameter value limits for the output
programmable resistance.
5.5.7 Protection
The protection functions that can be configured from this screen only apply to user programmable
protections. All hardware protection functions such as temperature (OTP) always enabled and
cannot be edited. To edit any protection setting, select the relevant field and enter a new value
using [0]~[9] keys or the on-screen decimal keypad.
5.5.7.1 OVP
The OVP setting range is from 0.0V through 1.10 x Rated voltage. The delay time setting is
from 0.001s through 10s.
5.5.7.2 OCP
The OCP setting range is from 0.0A through 1.10 x Rated current. The delay time setting is
from 0.001s through 10s.