Menu operation
50
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
Menu operation
Press the
Load
soft key to download all the settings to the unit. Then the page will jump to the
following screen.
Parameter ranges are:
NO.,
select the program file.
Repeat,
setting the repeat count of the selected program file. A zero repeat count indicates
infinite looping.
Trigger,
press this soft key to execute the selected list file. Once pressed, it changes to
Stop
.
Pause,
press this soft key to pause the output. Once pressed, it changes to
Continue
. The unit
will continue to execute the list file after pressing the
Continue
soft key.
5.9.1.3 Step mode
The step mode allows the output state to transition from its present setting to a new output
state using one or more discrete voltage, current, power or resistance. This represents a STEP
function as long as at least one of the parameters in the STEP differs from the present value.
Press the
Edit
soft key to enter edit mode.
Parameter ranges are:
Step NO.,
Step file NO.
Count,
set the repeat count.
∆T,
dwell time between steps.
Sweep,
power sweep function enable or disable.
Save,
save edits to the memory when done.
When the Step edit are complete, press the
Save
soft key to save all changes made to the
step file.
Note:
Failure to Save a transient list will cause it to be lost when the power source is turned off.
Press the [ESC] key turn to Load page.
Press the
Trigger
soft key to execute the step file. As the
Trigger
soft key is pressed, its label
changes to
Stop
. Use the
Stop
soft key to abort a transient in process.