25
24
Menu operation
Menu operation
After selecting Power+Sink mode, both the Power and Sink are displayed in the main screen.
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
●
Vdc S/R
Idc S/R
●
Average
●
CC/CV Prior
●
Hi-Variation
●
5.5.2 More Setting
5.5.2.1 Vdc S/R
This menu allows the user to set the slew rate for Vdc, which including:
Enable,
enable the slew rate setting.
Rise-V/ms,
used to set the voltage rise slew rate.
Fall-V/ms,
used to set the voltage fall slew rate.
5.5.2.2 Idc S/R
This menu allows the user to set the slew rate for Idc, which including:
Enable,
enable the slew rate setting.
Rise-A/ms,
used to set the current rise slew rate.
Fall-A/ms,
used to set the current fall slew rate.
5.5.2.3 Average
The Average soft key changes the number of the time a reading is averaged before the corre-
sponding measurement parameter display is updated. Available average values are LOW
(200ms), MID (50ms) and FAST (10ms).
The higher the number averaged, the slower the measurement update rate will be, so we
recommend you to choose the lowest acceptable number.
This screen allows control over the following output setting using these soft keys.