49
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
5.9.1.2 Program mode
The Program mode allows the user to edit the long output sequence with the already edited
list files.
Press the
Edit
soft key to enter edit mode.
Parameter ranges are:
PRO NO.,
Program file NO.
Step Count,
set the total steps of the current list file, which setting range is from 1 through 18.
Save,
save edits to the memory when done.
When the Program edit are complete, press the
Save
soft key to save all changes made to
the list.
Note:
Failure to Save a transient list will cause it to be lost when the power source is turned off.
Press the [ESC] key turn to Load page.
Menu operation
48
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
Press the
Load
soft key to download all the settings to the unit. Then the page will jump to the
following screen.
Parameter ranges are:
NO.,
select the list file.
Repeat,
setting the repeat count of the selected list file. A zero repeat count indicates infinite
looping.
Trigger,
press this soft key to execute the selected list file. Once pressed, it changes to
Stop
.
Pause
, press this soft key to pause the output. Once pressed, it changes to
Continue
. The unit
will continue to execute the list file after pressing the
Continue
soft key.
During transient execution, the Step = xx/xx will update as each step in the list executes. As are
Repeat setting for this list file, Test time and Time Left.
As the
Trigger
soft key is pressed, its label changes to
Stop
. Use the
Stop
soft key to abort a
transient list in progress.
Menu operation
Note
If the transient execution mode is set to
Step
, the output state of the power source will
remain at the last step value in the transient list until the next press of the
Trigger
soft key.
If a list execution is interrupted by pressing the
Stop
soft key, it will start at the beginning
of the list when in Cont. mode or resume form the current step when in
Step
mode.