80VDC
165VDC
250VDC
500VDC
750VDC
1000VDC
1500VDC
2250VDC
6000W
[1]
200A
-
-
32A
21A
-
-
-
12000W
[1]
400A
[1]
180A
-
64A
42A
32 A
21A
-
18000W
[1]
600A
-
[1]
180A
96A
63A
-
32A
21A
24000W
[1]
800A
[1]
360A
-
128A
84A
64A
42A
-
30000W
[1]
1000A
-
-
160A
105A
-
-
-
36000W
[1]
1200A
-
-
192A
126A
-
-
-
This series power supply in different power levels and either Advanced or Professional versions.
Please refer to the table below for the detailed difference between these configurations, optional
information as well.
Preface
Preface
Dear Customer,
Thank you for using this series High Power DC Power Supply, a product developed & manu-
factured by APM Technologies. We sincerely hope this product will meet your needs.
The sections outlined in this user manual are suitable for the following product models.
05
04
Contents
1
2
3
4
DDS arbitrary function generator
Solar panel I-V curve simulation function
Smart 3-stage charging algorithm simulation
Battery simulator function
Not supported
Supported
5
Built-in Standard Automotive Power Network
Voltage Curves
6
Remote I/O control and monitor card
7
LAN & GPIB communication interface
NO.
Description
Advanced Version
Professional Version
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
PROFESSIONAL
INNOVATIVE BRANDING
SERVICE
Power
Voltage
3U Units
6U Units
Model guide
SP
Stands for Power
Stands for Voltage
For example: SP80VDC12000W
Note: SP stands for Switching Power.
Not supported
Not supported
Not supported
Not supported
Optional feature
Optional feature
Supported
Supported
Supported
Supported
Optional feature
Optional feature
8
Continuous source & sink function
*
Optional feature
Optional feature
*
This option must be specified at the time of order as they are installed at the factory prior to shipment.
[1]
It is recommended that to decrease the output current to less than 90% of the rated current if the ambient
temperature exceeds 30
℃
.
Parallel/Series
...................................................................................................................
6
57
6.1 Configuring All Slave Units .......................................................................................... 57
......................................................................................... 58
6.2 Configuring The Master Unit
6.3
.............................................................................. 60
Parallel Mode Connection Diagram
6.4
...............................................................................
Series Mode Connection Diagram
61
62
7
Calibration
.........................................................................................................................
7.1 Calibration Equipment required .................................................................................. 62
........................................................................................ 62
7.2 Calibration Equipment Setup
................................................................................................... 63
7.3 Calibration Procedure
7.3.1 Accessing Calibration Mode................................................................................... 63
7.3.2 Voltage Setting & Measurement Calibration........................................................... 64
5
7.3.3 Current Setting & Measurement Calibration........................................................... 6
7.3.4 Power Setting & Measurement Calibration
6
............................................................. 6
6
7.3.5 Resistor Setting & Measurement Calibration.......................................................... 6
8 Installation
67
........................................................................................................................
8.1 Product Dimensions .................................................................................................... 67
8.2 Installing Rack Mount Handles ..................................................................................... 67
8.3 Installation of An Optional Interface Card ..................................................................... 68
8.4 Shelf Mounting Diagram of The Unit ...........................................................................
69
70
8.5 Input Connection ..........................................................................................................
72
8.6 Connection to DC Loads ..............................................................................................
74
8.7 Remote Sensing ...........................................................................................................
9 Recycling and Disposal
75
.................................................................................................
10 Contact Us
75
.....................................................................................................................
Appendix A Specifications
................................................................................................ 76
Appendix B Warranty
100
......................................................................................................
Appendix C Application Notes
102
........................................................................................
Issue PA (2020-06)