Menu operation
5.9.2.4 MCurr Share
Enable this function will keep output current balance between power modules in one chassis.
5.9.2.5 Timer Func
There are two timer control modes under this menu.
Menu operation
Power ON Timer, when this timer function is ON, it will activate the timer. After timer setting is
made, press the [ESC] key to return to the main screen. Once the timer reaches down to zero,
the supply will turn on the output automatically.
Power OFF Timer, when this timer function is ON, it will activate the timer. After timer setting is
made, press the [ESC] key to return to the main screen. After setting up the output current &
voltage and press [On/Off] to output, the screen will show the countdown of the timer. Once it
reaches down to zero, the supply will turn off the output automatically.
5.9.2.6 Counting Func
This function offers testing of the cutoff time of a breaker or a fuse.
The options include Voltage, Current and OFF.
In Voltage counting mode, set the basic output parameters according to test requirement. Press
[1]~[9] and [Enter] keys to set IL, which is the cut-off current for counting.
After the setting, press the [On/Off] key to turn on the output. The count starts from when output
voltage has reached the setting and stop until the breaker or fuse is open.