Status bar
3
This status displays the current operation mode, Local or Remote States, Alarm information
and the Date and time.
Soft keys
4
There are six soft keys located along the right hand side of the LCD screen. The labels of these
keys will change when selecting different screens. To select any of these soft keys, either press
the area on the touch LCD or press the actual button on the right hand side of the screen.
5.3 Navigation Page
In the main screen press the [ESC] key turn to navigation page. From this page tap the icon
can enter the wanted page directly.
5.4 Operation Modes Introduction
This series power supply supports three operation modes, including Local operation mode,
Remote operation mode and External analog control mode. The first two operation modes
can be selected by a connected computer without affecting the power supply output. Under
Remote control mode, all front panel keys except the decimal point key are locked. The default
is Local control mode. And the default setting values will be used if setting values are not saved
before restarting.
●
Power/Sink
More Setting
●
Load-2QO
●
*
Sink On/Off
●
*
Waveform
●
Limitation
●
Protection
●
Lock
●
The following soft keys are available in the setting screen to access these set up screen.
5.5 Setting Menu
*
These functions can be only available after purchasing Continuous source & sink function
5.5.1 Power/Sink Function
The user can set the operation mode. Available modes are Power only, Sink only or Power+Sink
combination. Use the stylus to click on the blue box under the corresponding option to select the
wanted operation mode.
Output settings and measurement zone for Sink mode
2
There are four input parameters can be set in this area, including Voltage, Current, Power and
Resistance. Only in Power+Sink mode, the Sink parameters will be displayed in this zone. If
the user enable Sink mode only, it will display at zone .
1
Output settings and measurement zone for Power mode
1
There are four output parameters can be set in this area, including Voltage, Current, Power
and programmable output resistance. The sink function will display only after it is enabled.