Enter 293 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
MinLength
barcode to set the minimum code length if necessary. Otherwise,
skip Steps (2)-(4)
(3)
Please refer to ASCII Code Table and Decimal/Hexadecimal Table in the appendix
to scan decimal value barcodes representing the desired number in the range of 0 to
255. For instance, to set its code length to be 2, scan
2
to assign the specified
decimal value “2”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
MaxLength
barcode and then repeat Steps (3)-(4) to set the maximum code
length, if necessary.
(6)
Scan
End
barcode to complete the configuration.
8-15-6.
Remove Leading Characters
Truncate Lead
parameter allows you to specify the number of characters which you intend
to remove forwards from the start of Plessey barcode. In doing so, you are able to format the
decoded message beforehand by taking out the necessary barcode parts and preserve the
desired segments for your benefit. Follow the below procedure to complete the
configuration.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
TrunLead
barcode to specify the number of characters to delete forwards from
the start of the decoded data.
(3)
Please refer to Decimal/Hexadecimal table in the appendix to scan decimal value
barcodes representing the desired number in the range of 0 to 255. For instance, to
remove first three digits out of every Plessey symbol, then scan
3
to assign the
specified decimal value “3”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
(Length: 1 digit / Range: 0-255)
*EB4E0*
TrunLead
EB4E0