Setting up your Operation Modes
7
7-2-1-24.
Set Timeout for SPP
Timeout is initiated when the device keeps waiting for an event to occur and thus remains
idle for a period of time during the data transmission. This parameter allows you to
specify the amount of time to elapse before timeout is officially triggered. Please follow
the below steps to configure the timeout period if the associated operations are performed
using USB HID interface.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
StdHidTxOtTime
barcode to configure timeout parameter for HID.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
set the timeout period to be 3 seconds, then scan
3
to assign the specified decimal
value “3”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*ABCE0*
StdHidTxOtTime
ABCE0
(Length: 1 digit / Range: 2-255/ Unit: 1000ms)