Enter 108 End
*/$%ENTR* *ZEND*
Setting up your Operation Modes
7
7-2-1-20.
Set Transfer Count for Time Delay for HID
This parameter allows you to specify the number of digits which has to be transmitted to
initiate a time delay referring to an intentional deferment of data transmission. Please
follow the below steps to set the transfer count for time delay if the associated operations
are performed using USB HID interface.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
StdHidTxCharGapCnt
barcode to configure the transfer count for time
delay for HID.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
initiate a timeout after 10 digits are transmitted, scan
1
first and then
0
to assign
the specified decimal value “10”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*AB1C7*
PO
AB1C7
*ABDE0*
StdHidTxCharGapCnt
ABDE0
(Length: 1 digit / Range: 0-255)
*AB1C8*
SK
AB1C8