UG-1262
Rev. B | Page 96 of 312
Bits
Bit
Name Settings Description
Reset Access
[12:10] TIARL
Set
R
LOAD
.
0x0 R/W
0
0
Ω.
1
10
Ω.
10
30
Ω.
11
50
Ω.
100
100
Ω.
101
1.6 kΩ. R
TIA
must be ≥2 kΩ.
110
3.1 kΩ. R
TIA
must be ≥4 kΩ.
111
3.6 kΩ. R
TIA
must be ≥4 kΩ.
[9:5] TIAGAIN
Set
R
TIA
.
0x0 R/W
0
Disconnect
R
TIA
.
1
200 Ω. Intended for oxygen sensor. TIA gain resistor is combination of R
LOAD
and fixed
series 110 Ω. Assume R
LOAD
= 10 Ω. Set by the TIARL bit. R
TIA
gain setting = 100 Ω −
R
LOAD
+ 110 Ω fixed. Overall TIA gain is 200.
10
1 kΩ. If R
LOAD
≤ 100 Ω, R
TIA
gain = (100 Ω − R
LOAD
) + 1 kΩ. If R
LOAD
> 100 Ω, R
TIA
gain is not
supported with a 1 kΩ R
TIA
.
11
2 kΩ. R
TIA
gain = 2 kΩ − (R
LOAD
− 100 Ω).
100
3 kΩ. R
TIA
gain = 3 kΩ − (R
LOAD
− 100 Ω).
101
4 kΩ. R
TIA
gain = 4 kΩ − (R
LOAD
− 100 Ω).
110
6 kΩ. R
TIA
gain = 6 kΩ − (R
LOAD
− 100 Ω).
111
8 kΩ. R
TIA
gain = 8 kΩ − (R
LOAD
− 100 Ω).
1000
10 kΩ. R
TIA
gain = 10 kΩ − (R
LOAD
− 100 Ω).
1001
12 kΩ. R
TIA
gain = 12 kΩ − (R
LOAD
− 100 Ω).
1010
16 kΩ. R
TIA
gain = 16 kΩ − (R
LOAD
− 100 Ω).
1011
20 kΩ. R
TIA
gain = 20 kΩ − (R
LOAD
− 100 Ω).
1100
24 kΩ. R
TIA
gain = 24 kΩ − (R
LOAD
− 100 Ω).
1101
30 kΩ. If R
LOAD
≤ 100 Ω, R
TIA
gain = (100 Ω − R
LOAD
) + 30 kΩ. If R
LOAD
> 100 Ω, R
TIA
gain =
30 kΩ − (R
LOAD
− 100 Ω).
1110
32 kΩ. R
TIA
gain = 32 kΩ − (R
LOAD
− 100 Ω).
1111
40 kΩ. R
TIA
gain = 40 kΩ − (R
LOAD
− 100 Ω).
10000
48 kΩ. R
TIA
gain = 48 kΩ − (R
LOAD
− 100 Ω).
10001
64 kΩ. R
TIA
gain = 64 kΩ − (R
LOAD
− 100 Ω).
10010
85 kΩ. R
TIA
gain = 85 kΩ − (R
LOAD
− 100 Ω).
10011
96 kΩ. R
TIA
gain = 96 kΩ − (R
LOAD
− 100 Ω).
10100
100 kΩ. R
TIA
gain = 100 kΩ − (R
LOAD
− 100 Ω).
10101
120 kΩ. R
TIA
gain = 120 kΩ − (R
LOAD
− 100 Ω).
10110
128 kΩ. R
TIA
gain = 128 kΩ − (R
LOAD
− 100 Ω).
10111
160 kΩ. R
TIA
gain = 160 kΩ − (R
LOAD
− 100 Ω).
11000
196 kΩ. R
TIA
gain = 196 kΩ − (R
LOAD
− 100 Ω).
11001
256 kΩ. R
TIA
gain = 256 kΩ − (R
LOAD
− 100 Ω).
11010
512 kΩ. R
TIA
gain = 512 kΩ − (R
LOAD
− 100 Ω).
[4:3]
IBOOST
Current Boost Control.
0x0
R/W
00
Normal
mode.
01
Increase amplifier output stage current to quickly charge external capacitor load.
Intended for use with high current sensors like oxygen electrochemical sensor.
10
Double TIA and potentiostat amplifiers overall quiescent current. Increases amplifier
bandwidth. Useful for diagnostic tests.
11
Double TIA and potentiostat amplifiers overall quiescent current and increase output
stage current. Increases amplifier bandwidth and output current capability. Useful for
diagnostic tests with high current sensors like the oxygen electrochemical sensor.
2 HALFPWR
Half Power Mode Select. Control bit to reduce active power consumption of TIA and
potentiostat amplifiers for sensor Channel 1.
0x0 R/W
0
Normal mode. Default value.
1
Reduce potentiostat amplifier and TIA current by half. Degrades performance.