Controller / User Interface | 4-3
Control Unit Display
The main control unit display allows viewing of different types of infor-
mation. You define which information to place on the first three lines of
the display by using the Display option from the Setup Key. Note that you
can also use the Display menu option to place your own text messages
on one or more of the first three lines. The last display line is reserved for
system and error messages.
If an alarm condition exists, alarm information in the form of an Up or
Down Arrow (corresponding to a high or low alarm) will appear next to
the oxygen reading on that display line. See the Alarm Key section for de-
tails on setting alarms. If a high hydrocarbon alarm condition is reached,
an Up Arrow will appear next to the high hydrocarbon message.
Auto Ranging Feature
If the oxygen reading falls below 0.5% O
2
, the display switches from the
percent scale to the PPM scale.
Control Unit Keys
This section provides an introduction to the main Series 2000 control unit
keys. Each of these keys provides a menu of choices that can be selected.
When in a menu, enter values by pressing the number keys.
Setup
Key
Allows you to set the control unit for your specific application.
Calibrate
Key
Allows you to set calibration parameters and to start calibrations.
Alarm
Key
Allows you to define parameters that control the alarm relays.
Analog Range
Key
Allows you to define parameters that control analog current outputs.
Help
Key
Allows you to access control unit on-line help.
Cancel
Key
Cancels you out of menu options.
Enter
Key
Allows you to confirm menu choices and values.
Summary of Contents for Thermox CEM O2/TM
Page 12: ...xii Thermox CEM O2 TM This page intentionally left blank...
Page 45: ...Installation 3 23 Figure 3 20 Current output connections example...
Page 47: ...Installation 3 25 Figure 3 21 Series 2000 standard alarm connections...
Page 49: ...Installation 3 27 Figure 3 22 Series 2000 controller RCU connections...
Page 51: ...Installation 3 29 Figure 3 23 Series 2000 2 wire RS 485 communications connections...
Page 53: ...Installation 3 31 Figure 3 24 Series 2000 4 wire RS 485 communications connections...
Page 56: ...3 34 Thermox CEM O2 TM This page intentionally left blank...
Page 116: ...5 26 Thermox CEM O2 TM This page intentionally left blank...
Page 137: ...Service and Parts 7 3 This page intentionally left blank...
Page 139: ...Service and Parts 7 5 Figure 7 1 Cell replacement...
Page 143: ...Service and Parts 7 9 Figure 7 3 Furnace replacement...
Page 162: ...B 4 Thermox CEM O2 TM This page intentionally left blank...
Page 166: ...C 4 Thermox CEM O2 TM This page inentionally left blank...
Page 168: ...D 2 Thermox CEM O2 TM This page intentionally left blank...