8. Rotate the bottom flap lever (Fig. 259/1)
across the group of holes (Fig. 259/2).
Open the bottom flaps.
The metered seed flows into the collection
bucket.
9. Set the bottom flap lever in the group of
holes (Fig. 259/2), like for the last seeding
operation, as soon as the collection bucket
is full.
Fig. 259
10. Empty the collection bucket (Fig. 260/1).
11. Repeat the procedure until the seed hopper
and the seed housing are empty.
Fig. 260
12. To empty the metering wheels, like for
calibration,
turn the central key to the left
briefly run the seeding shaft drive
motor, see "ISOBUS" operating
manual.