CHAPTER 5. OPERATING INSTRUCTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
5-20
990-371
10.
Return to the
RUN
screen and
increase the weld time by 1-2 ms.
Make several welds and verify
that the upper voltage limit is
reached for every weld, and the
weld pulse stops before the end
of the programmed weld time.
Weld to a Limit Waveform
11.
Make several more welds and inspect them for consistency of weld quality and/or weld strength.
NOTE:
When using the Weld to a Limit function, always select a monitor mode that is
different
from the feedback mode. For example:
•
If you are welding in constant current, put limits on voltage.
•
If you are welding in constant voltage, put limits on current.
•
If you are welding in constant power, put limits on current or voltage.