CHAPTER 5. OPERATING INSTRUCTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
5-6
990-371
8.
Press the
COOL
key to enter the amount of time for the cool period after Pulse 1. Use the
numeric keypad to enter the time or use the arrows. Enter
0.5
milliseconds.
9.
Program Pulse 2 by repeating Steps 3 through 7 above using the keys for Pulse 2, entering the
value
0
in each step.
10.
Press the
HOLD
key to enter the amount of time for the hold period after the weld. Use
the numeric keypad or the arrows. Enter a time between
0
and
999
milliseconds. We
recommend at least
50
milliseconds as weld strength is formed in the hold time.