CHAPTER 5. OPERATING INSTRUCTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
5-7
Dual-Pulse Weld Schedule
1.
Press the
SCHEDULE
key, then select a Weld Schedule using
either
the
▲▼
arrows
or
the numeric keypad.
2.
Press the
SQUEEZE
key to enter the squeeze time before the weld. Use the numeric
keypad to enter the time or use the
▲▼
arrows. Enter a time between
0
and
999
milliseconds.
3.
Press the
PULSE 1 UPSLOPE
key to enter the amount of time for the Weld Pulse 1
upslope
. Use the numeric keypad to enter the time or use the
▲▼
arrows. Enter a time
between
0
and
99
milliseconds.
4.
Press the
PULSE 1 WELD
key to highlight the
bottom line
of the LCD to enter the weld
time. Use the numeric keypad to enter the time or use the
▲▼
arrows. Enter a time
between
0
and
99
milliseconds.
5.
Press the
PULSE 1 WELD
key again to highlight the
middle line
of the LCD to enter
weld
energy
. Use the numeric keypad to enter the
energy level
or use the
▲▼
arrows. The
Power Supply output ranges are:
•
Current:
from 0.1
→
2.4 kA
•
Voltage:
0.2
→
9.999 V
•
Power:
0.05
→
9.999 kW
6.
Perform
one
of the following to program the Pulse 1 feedback mode:
•
From the
CONTROL
keys section on the front panel, press the
kA
key to program
current
as the feedback mode.
•
From the
CONTROL
keys section on the front panel, press the
V
key to program
voltage
as the feedback mode.
•
From the
CONTROL
keys section on the front panel, press the
kW
key to program
power
as the feedback mode.
7.
Press the
PULSE 1 DOWNSLOPE
key to enter the amount of time for the Weld Pulse 1
downslope
. Use the numeric keypad to enter the time or use the
▲▼
arrows. Enter a
time between
0
and
99
milliseconds. Note that in combo mode when the unit reaches a
constant current, any time programmed in this segment will be added to the weld at the
constant current level.