990-371
Command
SYSTEM {READ | SET}
<crlf>
[
parameter_name value
<crlf>]
<lf>
Control State
Any
Description
Provides control over the Power Supplies system parameters. When used with the "
READ
"
keyword, all system parameters are returned (see
SYSTEM
under Power Supply Originated
Commands). When used with the "
SET
" keyword, the host may set (change) the value of one
or more of the system parameters.
The following is a list of valid literal substitutions for the
parameter_name
and
value
variables:
LIGHT
{ light_value }
LCD contrast
LOUDNESS
{ loudness_value }
Buzzer Loudness
BUZZER
{ OFF | ON }
end of cycle buzzer
DISPLAY
{ PEAK | AVG }
Display mode
SWSTATE
{ switch_state }
Input Switch Type
CTSTATE
{ switch_state }
Control Signals Type
FIRESW
{ AUTO | REMOTE | NONE }
Firing Switch Type
GRAPH
{ OFF | ON }
Update Graph
WELDABORT
{ OFF | ON }
Footswitch weld abort
DEBOUNCE
{ NONE | 10 | 20 | 30 }
Switch debounce time in
msec
These parameters pertain to the settings of the option menus available via the front panel user
interface.
light_value
is a number 0 to 100 for brightness of the LCD. 0 is dark and 100 is the
brightest.
loudness_value
is a number 0 to 100 for buzzer loudness. 0 is off and 100 is the loudest.
switch
_state:
{ MECHOPEN | MECHCLOSED | OPTOOPEN | OPTOCLOSED
| PLC0V | PLC24V}