APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
E-9
P2LDLY1
{delay_value}
Pulse 2 Lower Delay Start Time For
Lower Limit
P2LDLY2
{delay_value}
Pulse 2 Lower Delay End Time For
Lower Limit
P2UDLY1
{delay_value}
Pulse 2 Upper Delay Start Time For
Upper Limit
P2UDLY2
{delay_value}
Pulse 2 Upper Delay End Time For
Upper Limit
limit_value
is the parameter that specifies the range of the valid readings. If the reading was
within the range of the
limit_value
, no alarm will occur. If the reading was out of the valid
range, an alarm will occur. If the monitor type is KA, the
limit_value
is in unit of 1 A. If the
monitor type is V, the
limit_
value is in unit of 1 mV. If the monitor type is kW, the
limit_
value
is in unit of 1 W. The valid number for
limit_value
is 1 through 9999 and 0 is for none.
The
delay_value
is the parameter that defines the time for the given period in 0.1 ms. Valid
range is from 0 to 99. Lower delay value is only valid during WELD time. Upper delay value
is valid during UP time, WELD time, and DOWN time.
Command
RELAY {READ | SET}
<crlf>
[
parameter_name value
<crlf>]
<lf>
Control State
Any except while welding
Description
Provides control over the Power Supply schedule parameters for relay settings. When used
with the "
READ
" keyword, the relay settings of the currently loaded schedule are returned (see
RELAY
under Power Supply Originated Commands). When the "
SET
" keyword is used, the
host may set (change) the value of one or more of the relay settings of the currently loaded
schedule. The following is a list of valid literal substitutions for the
parameter_name
and
value
variables:
ACTIVE1
{ HIGH | LOW }
Relay 1 Active High or Active Low
CONDITION1
condition_value
Relay 1 Active Conditions
SUBCOND1
extended_condition_value
Relay 1 Extended Conditions.
ACTIVE2
{ HIGH | LOW }
Relay 2 Active High or Active Low
CONDITION2
condition_value
Relay 2 Active Conditions
SUBCOND2
extended_condition_value
Relay 2 Extended Conditions.
ACTIVE3
{ HIGH | LOW }
Relay 3 Active High or Active Low
CONDITION3
condition_value
Relay 3 Active Conditions
SUBCOND3
extended_condition_value
Relay 3 Extended Conditions.
ACTIVE4
{ HIGH | LOW }
Relay 4 Active High or Active Low
CONDITION4
condition_value
Relay 4 Active Conditions
SUBCOND4
extended_condition_value
Relay 4 Extended Conditions.
condition
_value:
{ ALARM | LIMITS | WELD | END | P1HI | P1LOW | P2HI
| P2LOW | MG3 }
NOTE: extended_condition_value:
P1HI, P1LOW:
Pulse 1 hi/low limit reached.
P2HI, P2LOW:
Pulse 2 hi/low limit reached.