CHAPTER 5. OPERATING INSTRUCTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
5-10
990-371
1.
Press the
SCHEDULE
key, then select a Weld Schedule using
either
the
▲▼
arrows
or
the numeric keypad. Fire the welder and view the output waveform (shaded graph) on
the display.
2.
From the
MONITOR
keys section on the front panel, press the
,
,
, or
key to view the desired waveform. Note that the other monitor keys do not have graphical
waveforms.
3.
Toggle the Pulse 1 weld time/energy selector key to select the
upper
limit field for the
weld period. Use the numeric keypad or the
▲▼
arrows to enter the
upper limit
value
for the Pulse 1 weld period.
4.
Perform
one
of the following to program the Pulse 1 monitor limit mode:
•
Press the
kA
key to program
current
as the limit mode.
•
Press the
V
key to program
voltage
as the limit mode.
•
Press the
kW
key to program
power
as the limit mode.
•
Press the
Ώ
key to program
resistance
as the limit mode.
5.
Toggle the Pulse 1 weld time/energy selector key to select the
lower limit
field for the
weld period. Enter the lower limit value for the Pulse 1 weld period.
NOTE:
In order for a Pulse 1
lower limit
to be programmed, you must
first
program a
Pulse 1 upslope in the weld schedule.
The lower limit mode (current, voltage, or power) will automatically be the same as the
upper limit mode programmed in Step 4.
6.
Press the
COOL
weld period key.
This will bring up the
PULSE 1
OUT OF LIMITS ACTION
screen.
This screen allows you to select
the action that the Power Supply
will take if the Pulse 1 upper or
lower limits are exceeded. You
have
four
choices:
PULSE 1 OUT OF LIMITS ACTION
1. none
2. STOP WELD
3. INHIBIT PULSE 2
4. PART CONDITIONER (Stop Pulse1)
NUMBER Select,
Page, RUN or MENU
•
NONE
takes no action if upper or lower energy limits are exceeded.
•
STOP WELD
stops the weld immediately during Pulse 1, and prevents Pulse 2 from
firing (if applicable).
•
INHIBIT PULSE 2
stops the weld at the end of Pulse 1, and prevents Pulse 2 from firing.
This function will not operate if both pulses are joined
without
a cool time.