APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
E-11
Command
ALARM {READ | CLEAR | SET error_number | DISPLAY
alarm_message_string}
<crlf><lf>
Control State
Any
Description
Provides access to the Power Supply alarm logic. When used with the "READ" keyword, the
current error condition value is returned. See Appendix A. for list of alarm messages. When
the "CLEAR" keyword is used, all alarm conditions are canceled. When the "SET" keyword is
used, the host may invoke an error identified by error_number. When the "DISPLAY" keyword
is used, an error condition can be created with any message desired. The length of the error
message must be limited to 40 characters or less. No help message will be available in
connection with this created error message.
Command
SECURITY {OFF | SCHEDULE | SYSTEM | CALIBRATION}
<crlf><lf>
Control State
Any
Description
Allows control of the system security mode.
“OFF” sets all security status Power Supply to “OFF.”
“SCHEDULE” sets the schedule lock to “ON.”
“SYSTEM” sets the system lock to “ON.”
“CALIBRATION” sets the calibration lock to “ON.”