CHAPTER 3: SYSTEM CONFIGURATION
HF-2500A HIGH FREQUENCY WELD CONTROL
3-8
990-371
8. RESET TO DEFAULTS
From the
MAIN MENU
, press the
8
key to go to the
RESET TO DEFAULTS
menu, as shown at the
right. Through this menu, you may reset all
system programmed parameters and all weld
schedules to the original factory default settings
(see the table below).
<RESET TO DEFAULTS>
1. RESET SYSTEM PARAMETERS
2. RESET ALL SCHEDULES
3. RESET SCHEDULE LIMITS
Number Select an item, RUN or MENU
Factory Default System Parameters
System Parameter
Default Setting
System Parameter
Default Setting
Foot Switch Weld Abort
OFF
Weld Counters
All “0”
Switch Debounce Time
10 ms
Communication Role
CLIENT
Firing Switch
AUTO
Baud Rate
38.4 K
Display Contrast
50%
ID Number
1
Buzzer Loudness
40%
Relays 1,2,3 and 4
ON WHEN ALARM
End of Cycle Buzzer
OFF
Update Graph After
Weld
ON
Language
ENGLISH
Do Test Weld
ALWAYS
1. RESET SYSTEM PARAMETERS
1.
With the reset to defaults screen
displayed, press the
1
key. This will
bring up the
RESET SYSTEM
PARAMETERS
query menu, as shown at
the right.
<RESET SYSTEM PARAMETERS?>
1. NO
2. YES
Number Select,
Page, RUN or MENU
2.
Press the
2
key to select
YES
. This will automatically reset the system to the factory and return
the screen to the
RESET TO DEFAULTS
display.
Summary of Contents for HF-2500A
Page 1: ...990 371 REV J HIGH FREQUENCY WELD CONTROL HF 2500A OPERATION MANUAL...
Page 88: ......
Page 100: ......
Page 118: ......
Page 144: ......