APPENDIX C: CALIBRATION
HF-2500A HIGH FREQUENCY WELD CONTROL
C-2
990-371
Calibration Procedure
Initial Calibration Setup
1.
Connect the calibration setup to the
Power Supply as shown.
2.
Turn the Power Supply ON.
3.
In the
MAIN MENU
press
4
to enter the
calibration screen.
<MAIN MENU>
1. SETUP
6. COMMUNICATIONS
2. WELD COUNTERS
7. RELAY
3. COPY A SCHEDULE
8. RESET DEFAULTS
4. CALIBRATION
9. CHAIN SCHEDULES
5. SYSTEM SECURITY
Number Select an item
4.
Press
1
for
HF-2500A CALIBRATION
which will bring up the
CAUTION
screen
on the right. Press the
▼
arrow.
CAUTION
CALIBRATION SHOULD BE PERFORMED BY A
QUALIFIED TECHNICIAN ONLY.
REFER TO MANUAL FOR CALIBRATION SETUP.
▼
next, MENU
5.
Press
2
to calibrate the HF-2500A.
<PRE-CALIBRATION>
1. TEST HF25 (T-232 REQUIRED)
2. CALIBRATE HF25
3. RESET CALIBRATION
4. SET CURRENT SHUNT VALUE
5. TEST SERIAL PORT
Menu