APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
E-15
Command
REPORT type_of_report number_of_reports
<crlf>
report
<crlf> report <crlf> . . . .
report
<crlf><lf>
Control State
Any
Description
Returns the requested number of weld reports. First field is the type of reports to be sent.
The second field is the number of reports sent. Then follows the packets of report. One report
pack holds the information about the weld requested. Each report packet is separated by
<crlf> and this Command ends with <crlf><lf>.
Type_of_report:
This field defines the type of report that was requested by the host computer.
The fields in the report packet are separated with a comma and all fields are in integer format.
There are always 24,027 fields in a report packet.
OLD:
Number_of_reports:
This is the number of reports that shall be included in this command.
If the host computer requests more weld data than is available in the weld data buffer, the
Power Supply sends only the weld reports in the weld buffer and the
number_of_reports
is
the number of weld reports available in the weld data buffer. After the report is sent to the
host computer, the Power Supply does not erase the weld data sent to the host from the weld
data buffer. You must use the
REPORT ERASE #
command to erase weld data from the
weld buffer.
unit_number:
The unit number assigned to the unit.
Schedule
_
number
:
The schedule number of the weld.
weld
_
status
:
The status of the weld.
Average_current_1
:
The average current of pulse 1 (in A).
Average_voltage
_
1
:
The average voltage of pulse 1(in mV).
peak_current_1:
The peak current of pulse 1 (in A).
peak_voltage_1:
The peak voltage of pulse 1 (in mV).
average_power_1:
The average power of pulse 1 (in W).
peak_power_1:
The peak power of pulse 1 (in W).
average_resistance_1:
The average resistance of pulse 1 (in 10
-5
Ω
).
peak_resistance_1:
The peak resistance of pulse 1 (in 10
-5
Ω
).
null_1:
Always zero
null_2:
Always zero
average_current_2:
The average current of pulse 2 (in A).
average_voltage_2:
The average voltage of pulse 2(in mV).
peak_current_2:
The peak current of pulse 2 (in A).
peak_voltage_2:
The peak voltage of pulse 2 (in mV).
average_power_2:
The average power of pulse 2 (in W).
peak_power_2:
The peak power of pulse 2 (in W).
average_resistance_2:
The average resistance of pulse 2 (in 10
-5
Ω
).
peak_resistance_2:
The peak resistance of pulse 2 (in 10
-5
Ω
).
null_3:
Always zero
null_4:
Always zero
Weld_count:
The number of this weld assigned by the unit