APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
E-19
Command
SCHEDULE
schedule_number
<crlf>
ENG1
weld_energy
<crlf>
FEEDBACK1
{ KA | V | KW }
<crlf>
ENG2
weld_energy
<crlf>
FEEDBACK2
{ KA | V | KW }
<crlf>
SQUEEZE
squeeze_time
<crlf>
UP1
weld_time
<crlf>
WELD1
weld_time
<crlf>
DOWN1
weld_time
<crlf>
COOL
weld_time
<crlf>
UP2
weld_time
<crlf>
WELD2
weld_time
<crlf>
DOWN2
weld_time
<crlf>
HOLD
hold_time
<crlf>
RINDEX1
resistance_index<crlf>
RINDEX2
resistance_index<crlf>
EINDEX1
energy_index<crlf>
EINDEX2
energy_index<crlf>
<lf>
Control State
Any
Description
Reports the settings of the currently loaded Power Supply schedule parameters. The
schedule_number
variable identifies which schedule is currently loaded, and may be any value
from 0 to 99.
squeeze_time
and
hold_time
are the parameter that defines the time for the given period in 1
msec. Valid range is from 0 to 999.
weld_time
is equivalent to 0.01 for Increments from 0.1 to 0.99 ms and increments of 0.1 ms for
1.0 to 9.9 ms and increments of 1.0 ms for 10.0 to 99.0 msec. (see table below)
HOST
POWER SUPPLY
Increments
Range
Time Range
Increments
0.01
0.1 - 0.99
0.1 - 0.99 ms
0.01 ms
0.1
1.00 - 9.90
1.0 - 9.9 ms
0.1 ms
1.0
10.00 - 99.0
10.0 - 99.0 ms
1 ms