HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
C-1
APPENDIX C
Calibration
Section I. Calibrating the Power Supply
Overview
The Power Supply is calibrated by the software, using inputs from a calibration setup during a weld
process. Following a few calibration inputs, the Power Supply will adjust itself and store the calibration
values in RAM, where they will be used as standards for the operational welding parameters.
CAUTION:
Only authorized personnel should perform this procedure.
Calibration Equipment Required
The required equipment for the setup is as follows:
•
2 weld cables, No. 2/0, 1ft (30 cm) long, Pt # 2/0 BB11
•
1000μΩ coaxial shunt
resistor accurate to ±0.2%.
Source for shunt resistor: Model R7500-8
T & M Research Products, Inc.
139 Rhode Island Street NE
Albuquerque, NM 87108
Telephone: (505) 268-0316
•
Shielded voltage sense cable, Pt # 4-32998-01
•
Digital oscilloscope, Tektronix 724C or equivalent
•
Male BNC to dual binding post
•
2-wire, normally open switch for weld initiation, mating connector Pt # 520-001
•
Coaxial BNC-to-BNC cable