APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
E-21
Command
RELAY
<crlf>
ACTIVE1
{ HIGH | LOW }
<crlf>
CONDITION1
{
condition_value
}<crlf>
SUBCOND1
{
extended_condition_value
}<crlf>
ACTIVE2
{ HIGH | LOW }
<crlf>
CONDITION2
{
condition_value
}<crlf>
SUBCOND2
{
extended_condition_value
}<crlf>
ACTIVE3
{ HIGH | LOW }
<crlf>
CONDITION3
{
condition_value
}<crlf>
SUBCOND3
{
extended_condition_value
}<crlf>
ACTIVE4
{ HIGH | LOW }
<crlf>
CONDITION4
{
condition_value
}<crlf>
SUBCOND4
{
extended_condition_value
}<crlf>
<lf>
condition_value:
{ ALARM | LIMITS | WELD | END | P1HI | P1LOW | P2HI
| P2LOW}
extended_condition_value:
{ P1HI | P1LOW | P2HI | P2LOW}
NOTES:
P1HI, P1LOW:
Pulse 1 low/hi limit reached.
P2HI, P2LOW:
Pulse 2 low/hi limit reached.
Control State
Any
Description
Reports the relay settings.
Command
SECURITY
<crlf>
SCHEDULE
{ ON | OFF }
<crlf>
SYSTEM
{ ON | OFF }
<crlf>
CALIBRATION { ON | OFF }
<crlf><lf>
Control State
Any
Description
Returns the current status of the security settings.