CHAPTER 3: SYSTEM CONFIGURATION
HF-2500A HIGH FREQUENCY WELD CONTROL
3-2
990-371
From the
SETUP 1
screen, press the key.
The
SETUP 2
screen is shown on the right with
typical settings.
<SETUP, page 2 of 3>
1. DISPLAY CONTRAST
:
50
2. BUZZER LOUDNESS
:
40
3. END OF CYCLE BUZZER
:
OFF
4. UPDATE GRAPH AFTER WELD
:
ON
5. LANGUAGE
:
ENGLISH
Number Select an item,
Page, RUN or MENU
From the
SETUP 2
screen, press the key.
The
SETUP 3
screen is shown on the right with
typical settings.
<SETUP, page 3 of 3>
1. DO TEST WELD
:
ALWAYS
Number Select an item,
Page, RUN or MENU
2. WELD COUNTER
1.
From the
MAIN MENU
, press the
2
key to
go to the
WELD COUNTERS
screen. The
total welds counter increments each time
a weld is made in any weld schedule.
<WELD COUNTERS>
1. TOTAL WELDS
:
0000000
2. OUT OF LIMITS HIGH
:
000000
3. OUT LIMITS LOW
:
000000
4. WITHIN LIMITS
:
000000
Number Select an item, , RUN or MENU
NOTE:
The Power Supply breaks down the weld count into three additional categories, as
determined by the energy limits monitor: rejects due to higher than programmed weld energy,
rejects due to lower than programmed weld energy, and the number of welds within limits.
2.
To select the weld counters, press the
1
,
2
,
3
or
4
key to select the desired weld counter. The
example below shows the
TOTAL WELDS
screen.
3.
To reset the counter, press the
0
key.
4.
To input a preset number, use the
numeric keys.
5.
If you accidentally reset the wrong
counter, press the period (
.
) key. The
original count will reappear. Press the
MENU
key to return to the
MAIN MENU
screen.
<WELD COUNTERS>
1. TOTAL WELDS
: 0000000
NUMBER Change, [.] Restore,
Page, MENU