CHAPTER 5. OPERATING INSTRUCTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
5-8
990-371
8.
Press the
COOL
key to enter the amount of time between Pulse 1 and Pulse 2. Use the
numeric keypad to enter the time or use the
▲▼
arrows. Enter a time between
0
and
99
milliseconds. We recommend at least 2 milliseconds.
9.
Program Pulse 2 by repeating Steps 3 through 7 above using the keys for Pulse 2, entering
appropriate values for Pulse 2.
10.
Press the
HOLD
key to enter the amount of time for the hold period after the weld. Use
the numeric keypad to enter the time or use the
▲▼
arrows. Enter a time between
0
and
999
milliseconds. We recommend at least
50
milliseconds.