CHAPTER 3: SYSTEM CONFIGURATION
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371
3-3
3. COPY A SCHEDULE
The Power Supply can store
99
(numbered
1
through
99
) individual weld energy profiles. This
function allows you to copy any weld schedule
from one numbered weld schedule to another
numbered weld schedule
1.
From the
MAIN MENU
, press the
3
key to
go to the
COPY
SCHEDULE
screen.
<COPY SCHEDULE>
COPY SCHEDULE [ 1 ] TO SCHEDULE [2 ]
Enter NUMBERS followed by SCHEDULE
2.
Using the numeric keys, enter
1
in the
source schedule number field.
3.
Press the key to select the destination
schedule number field.
4.
Using the numeric keys, enter
2
in the
destination schedule number field.
<COPY SCHEDULE>
COPY SCHEDULE [ 1 ] TO SCHEDULE [2 ]
Enter NUMBERS followed by SCHEDULE
5.
Press the
SCHEDULE
key to copy the schedule and exit the screen.
6.
Press the
MENU
key to return to the main menu. The contents of Weld Schedule 1 will be copied
to Weld Schedule 2, overwriting the previous contents of Weld Schedule 2. Note that this
function will copy schedule settings, monitor limits and envelope offsets, but it will not copy the
reference waveforms for envelope limits.
4. CALIBRATION
From the
MAIN MENU
, press the
4
key to go to the
CALIBRATION
screen. Refer to the appendix for
calibration setup.
<*** CAUTION ***>
CALIBRATION SHOULD BE PERFORMED BY A
QUALIFIED TECHNICIAN ONLY.
REFER TO MANUAL FOR CALIBRATION SETUP
Next, RUN or MENU
5. SYSTEM SECURITY
From the
MAIN MENU
, press the
5
key to go to up
SYSTEM SECURITY
screen. With this screen, you
can protect the weld schedules from unauthorized
changes by programming the Power Supply with
a user-defined protection code.
<SYSTEM SECURITY>
1. SCHEDULE LOCK
:
OFF
2. SYSTEM LOCK
:
OFF
3. CALIBRATION
:
OFF
NUMBERS Select an item, RUN or MENU