APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
E-6
990-371
Command
OHMS
<crlf><lf>
Control State
Any
Description
Requests the Power Supply to report the sampled resistance data of the last weld. Power Supply
shall return with OHMS report. See OHMS command under Power Supply Originating
Commands section.
Command
STATE {READ | RUN | MENU
}<crlf><lf>
Control State
Any
Description
Commands the Power Supply to identify its current state ("READ" keyword, see STATE
command under Power Supply Originating Commands section) or go to either RUN state or
PROGRAM state.
Command
LOAD
{
schedule_number
}<crlf><lf>
Control State
RUN state
Description
Selects the schedule_number as the currently loaded schedule. schedule_number may be any
number from 0 to 99. There must be a space between LOAD and schedule_number.
Command
COUNTERS {READ | SET}
{
TOTAL | HIGH | LOW | GOOD}
<crlf><lf>
Control State
Any
Description
Requests the Power Supply to return the Power Supply weld counter contents.
TOTAL
:
Returns the total number of weld counter.
HIGH
:
Returns the out of limits high counter.
LOW:
Returns the out of limits low counter.
GOOD:
Returns the within limits counter.
Command
REPORT {OLD | | ERASE} number
<crlf><lf>
Control State
Any
Description
Requests the Power Supply to send the weld report.
OLD
: requests to send the number of oldest weld reports since the last data collection.
The reported weld data will be erased.
ERASE:
a request to erase the number of oldest welds.
number:
the number of weld data to be sent.
If the number is greater than the number of weld data in the buffer, less than the number of weld
data will be sent.
NOTE:
There must be at least one space between each of the three field.